DelcoRemy Homepage Client Login
Delco Remy Heavy Duty Electrical Systems

    About Delco Remy

    Alternators

    Starters

    Literature

    Literature Downloads

    Service Manuals/Instr. Sheets

    Technical/Fleet

    Distributor/Dealer Locator

    Global Customer Support

    Logo Gear

    Contact Us


  Related Information
For Suppliers
 
Our corporate site:

www.remyinc.com
Visit our new European site:
www.remyinc.eu
  Press Releases
Regional Sales Team Map
Warranty
Part Number Cross-Reference
Quick Reference Guide
Technology
 
Delco Remy
Heavy Duty Electrical Systems
1-800-372-0222


Spacer
  


24SI 24SI Pad Mount
Part Number Reference Table (.pdf) | J180 Hinge Mount Service Parts (.pdf) |
Pad Mount Service Parts (.pdf) | Instruction Sheets (.pdf) | Service Manuals (.pdf)

24SI Design Features and Benefits:
• Dual Internal Fans create cool environment for bearings and electronics
• Built-in protection from water and other contaminants with dual spacers and slingers
• Multi-function regulator with an environmentally sealed packard connector features auto-start and optional remote sense capability
• Smaller slip rings with higher resistance to brush bounce extend service life
• SRE cover protects electronics while managing airflow
• Easy installation with one-wire connection
• Advanced design “Avalanche” press fit diodes provide long life, protection from electrical system spikes

24SI Detailed Specifications

Performance Output:
100 Amps - 12 Volts
130 Amps - 12 Volts
145 Amps - 12 Volts
160 Amps - 12 Volts
70 Amps - 24Volts

Construction:
Brush

Stator Diameter:
144mm

Length (to end of shaft):
223mm

Typical Weight:
7.6 kg (16.7 lbs)

Speed Capability:
Continuous - 10,000 rpm
Intermittent 12,000 rpm

Inlet Temperature Limits:
Low: -40°C / -40°F
High: 105°C / 221°F

Polarity:
Negative Ground

Rotation:
Clockwise

24SI PAD Mount Detailed Specifications

Performance Output:
100 Amps - 12 Volts
130 Amps - 12 Volts
145 Amps - 12 Volts
160 Amps - 12 Volts
70 Amps - 24Volts

Construction:
Brush

Stator Diameter:
144mm

Length (to end of shaft):
223mm

Typical Weight:
7.6 kg (16.7 lbs)

Speed Capability:
Continuous - 10,000 rpm
Intermittent 12,000 rpm

Inlet Temperature Limits:
Low: -40°C / -40°F
High: 105°C / 221°F

Polarity:
Negative Ground

Rotation:
Clockwise

24SI Air Flow Draws air from drive end and terminal end over electronics and internal components and out frame air vents for cooler internal alternator temperature.

Conventional External Fan Alternator Draws air from terminal end toward the external fan. Hotter internal alternator temperature.
SAE J180 Hinge Standard:
PAD Mount System:
footer